HIOKI IM3570 Impedance Analyzer
• High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode
• High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
|
Measurement modes |
LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode |
|
Measurement parameters |
Z, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q |
|
Measurement range |
100 mΩ to 100 MΩ, 12 ranges (All parameters are determined according to Z) |
|
Display range |
Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ±(0.000000 [unit] to 9.999999G [unit], Absolute value display for Z and Y only θ : ±(0.000° to 180.000°), D : ±(0.000000 to 9.999999) Q : ±(0.00 to 99999.99), Δ % : ±(0.0000% to 999.9999%) |
|
Basic accuracy |
Z ±0.08% rdg. θ: ±0.05° |
|
Measurement frequency |
4 Hz to 5 MHz (5 digits setting resolution, minimum resolution 10 mHz) |
|
Measurement signal level |
Normal mode: V mode/CV mode: 5 mV to 5 Vrms (up to 1 MHz) 10 mV to 1 Vrms (1.0001 MHz to 5 MHz), 1 mVrms steps CC mode: 10 μA to 50 mArms (up to 1 MHz) 10 μA to 10 mArms (1.0001 MHz to 5 MHz), 10 μArms steps Low impedance high accuracy mode: V mode/CV mode: 5 mV to 1 Vrms (up to 100 kHz), 1 mVrms steps CC mode:10 μA to 100 mArms (100 mΩ and 1Ω ranges of up to 100 kHz), 10 μArms steps |
|
Output impedance |
Normal mode: 100 Ω, Low impedance high accuracy mode: 10 Ω |
|
Display |
5.7-inch color TFT, display can be set to ON/OFF |
|
Measurement time |
0.5 ms (100 kHz, FAST, display OFF, representative value) |
|
Functions |
DC bias measurement, Comparator, BIN measurement (classification), Panel loading/saving, Memory function |
|
Interfaces |
EXT I/O (handler), RS-232C, GP-IB, USB communication, USB memory, LAN |
|
Power supply |
90 to 264 V AC, 50/60 Hz, 150 VA max. |
|
Dimensions and mass |
330 mm (12.99 in) W × 119 mm (4.69 in) H × 307 mm (12.09 in) D, 5.8 kg (204.6 oz) |
|
Accessories |
Power cord × 1, Instruction manual × 1, PC communication instruction manual (CD-R) × 1 |
• LCR measurement, DCR measurement, sweep measurement, continuous measurement and high-speed testing achieved with one instrument
• High-speed testing, achieving maximum speeds of 1.5ms (1 kHz) and 0.5ms (100kHz) in LCR mode
• High-accuracy measurements, basic accuracy of Z parameter: ± 0.08%
• Perfect impedance analyzer for testing the resonance characteristics of piezoelectric elements, C-D and low ESR measurement of functional polymer capacitors, DCR and L-Q measurement of inductors (coils and
transformers)
• Perform frequency sweeps, level sweeps, and time interval measurements in analyzer mode