HIOKI FT3405 / FT3406 Digital Tachometers
• Dust-proof construction and drop-proof to 1 meter
• Wide measurement range of 0.5000 r/s (30.00 r/min) to 99990 r/min
|
|
FT3405 |
FT3406 |
|
Measurement method |
Non-contact: Using red visible-spectrum light and reflective tape. Contact: Using optional Contact Adapter. |
Non-contact: Using red visible-spectrum light and reflective tape. Contact: Using optional Contact Adapter. |
|
Measurement ranges Non-contact, AVG=ON |
Rotation (r/min) : (30.00 to 199.99) to (20000 to 99990), Rotation (r/s) : (0.5000 to 1.9999) to (200.0 to 1600.0), Period (ms) : (0.6000 to 1.9999) to (200.0 to 1999.9), Count : 0 to 999999 |
Rotation (r/min) : (30.00 to 199.99) to (20000 to 99990), Rotation (r/s) : (0.5000 to 1.9999) to (200.0 to 1600.0), Period (ms) : (0.6000 to 1.9999) to (200.0 to 1999.9), Count : 0 to 999999 |
|
Measurement ranges Contact, AVG=ON |
Rotation (r/min) : (15.00 to 199.99) to (2000 to 19999), Rotation (r/s) : (0.2500 to 1.9999) to (200.0 to 333.00), Period (ms) : (3.000 to 19.999) to (200.0 to 3999.9), Count : 0 to 999999 |
Rotation (r/min) : (15.00 to 199.99) to (2000 to 19999), Rotation (r/s) : (0.2500 to 1.9999) to (200.0 to 333.00), Period (ms) : (3.000 to 19.999) to (200.0 to 3999.9), Count : 0 to 999999 |
|
Measurement ranges Contact, AVG=ON |
Straight-line speed (meter/min) : (1.500 to 19.999) to (200.0 to 1999.9) Straight-line speed (meter/s) : (0.0250 to 1.9999) to (20.00 to 33.30) *Using with the Peripheral ring 9212 (option) |
Straight-line speed (meter/min) : (1.500 to 19.999) to (200.0 to 1999.9) Straight-line speed (meter/s) : (0.0250 to 1.9999) to (20.00 to 33.30) *Using with the Peripheral ring 9212 (option) |
|
Accuracy |
Up to 9999 counts: ±1 dgt. (AVG=ON), ±10 dgt. (AVG=OFF) 10000 counts or more: ±2 dgt. (AVG=ON), ±20 dgt. (AVG=OFF) 20000 counts or more (r/min mode only) : ±20 dgt. (AVG=ON), ±100 dgt. (AVG=OFF) Straight-line speed measurement only: ±0.5 % rdg. add to above-mentioned accuracy |
Up to 9999 counts: ±1 dgt. (AVG=ON), ±10 dgt. (AVG=OFF) 10000 counts or more: ±2 dgt. (AVG=ON), ±20 dgt. (AVG=OFF) 20000 counts or more (r/min mode only) : ±20 dgt. (AVG=ON), ±100 dgt. (AVG=OFF) Straight-line speed measurement only: ±0.5 % rdg. add to above-mentioned accuracy |
|
Non-contact measuring detection range |
50 mm (1.97 inch) to 500 mm (19.7 inch) |
50 mm (1.97 inch) to 500 mm (19.7 inch) |
|
Display refresh rate |
Approx. 0.5 to 10 times/s |
Approx. 0.5 to 10 times/s |
|
Functions (FT3406 only) |
N/A |
[Analog output] 0 to 1 V f.s., Accuracy: ±2 % f.s., Output resistance: 1 kΩ [Pulse output] 0 to 3.3 V, Output resistance: 1 kΩ, Can use with the AC adapter for power supply |
|
Dust and water proof |
IP50 (EN60529) |
IP50 (EN60529) |
|
Common functions |
MAX/MIN display, Display hold, Average, Auto power save, Buzzer sound, Drop-proof (1 m distance onto concrete surface) |
MAX/MIN display, Display hold, Average, Auto power save, Buzzer sound, Drop-proof (1 m distance onto concrete surface) |
|
Power supply |
LR6 (AA) alkaline battery ×2, Max. rated consumption 0.5 VA |
LR6 (AA) alkaline battery ×2, Max. rated consumption 0.5 VA |
|
Operating time |
Continuous use 30 hr |
Continuous use 25 hr |
|
AC power supply |
N/A |
AC adapter Z1004 |
|
Dimensions and mass |
71 mm (2.80 in)W × 186 mm (7.32 in)H × 38 mm (1.50 in)D, 230 g (8.1 oz) (including batteries) |
71 mm (2.80 in)W × 186 mm (7.32 in)H × 38 mm (1.50 in)D, 230 g (8.1 oz) (including batteries) |
|
Accessories |
Instruction manual ×1, Reflective tape 9211 ×1 sheet (30 pieces/ 12 mm (0.47 in) × 12 mm (0.47 in) per piece), Carrying case C0202 ×1, LR6 (AA) alkaline battery ×2 |
Instruction manual ×1, Reflective tape 9211 ×1 sheet (30 pieces/ 12 mm (0.47 in) × 12 mm (0.47 in) per piece), Carrying case C0202 ×1, LR6 (AA) alkaline battery ×2, *FT3406 only: Output cord L9094 ×1 |
• Convenient analog and pulse output functions
• Dust-proof construction and drop-proof to 1 meter
• Wide measurement range of 0.5000 r/s (30.00 r/min) to 99990 r/min
• Contact style testing available with optional contact adapter
• Convenient analog and pulse output functions (FT3406 only)
• Optional AC Adapter (FT3406 only)