• HIOKI 3159-02 Insulation/Withstand Tester

HIOKI 3159-02 Insulation/Withstand Tester

• Continuous testing of insulation (500/1000 V) and withstand voltage (500 VA transformer capacity)
• Insulation to withstand series test or withstand to insulation series test at auto mode, or individual test at manual mode
• Save up to 10 test settings each for the withstanding and insulation testing modes
• External I/O, RS-232C interface, Status output (relay contacts)
Model : HIOKI 3159-02

[Withstanding test section]

Testing voltage

0 to 2.5 kV / 0 to 5.0 kV AC, 2 range configuration 500 VA (30 minutes rated)

Voltage setting

Manual setting

Waveform/Frequency

Same as the power supply waveform, synchronized with the power supply

Current measurement

0.01 mA to 120 mA, True RMS rectified (digital display)

Voltage meter

Accuracy: ±1.5 % f.s. (digital), ±5 % f.s. (analog, f.s.=5 kV)

Current measurement

0.01 mA to 120 mA, (Average value rectified, effective value digital display)

Measurement range

2 mA/8 mA (0.01 mA resolution), 32 mA (0.1 mA resolution), 120 mA (1 mA resolution)

Voltage meter

Digital, Accuracy: ±1.5 % rdg. (f.s.=5.00 kV)

Judgment function

Window comparator method (Digital setting)

[Insulation test section]

Testing voltage

500 V DC, 1000 V DC, Unloaded voltage: 1 to 1.2 times rated voltage

Rated testing current

1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)

Measurement range, Accuracy

0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,

1000 MΩ to 2000 MΩ: ±8 % rdg.

Judgment function

Window comparator method (Digital setting)

[Timer section]

Setting range

0.5 to 999 s

[General section]

Monitor function

Output voltage, detected current, insulation resistance, Refresh rate: 2 times/s

Power supply

220 V AC, (50/60 Hz), 800 VA max.

Dimensions and mass

320 mm (12.60 in)W × 155 mm (6.10 in)H × 330 mm (12.99 in)D,

21.5 kg (758.4 oz)

Accessories

H.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1

    Continuous testing of insulation (500/1000 V) and withstand voltage (500 VA transformer capacity)

    Insulation to withstand series test or withstand to insulation series test at auto mode, or individual test at manual mode

    Save up to 10 test settings each for the withstanding and insulation testing modes

    External I/O, RS-232C interface, Status output (relay contacts)

Related Products

HIOKI ST9000 DISCHARGE DETECTION UPGRADE

HIOKI ST9000 DISCHARGE DETECTION UPGRADE