• HIOKI 9675 Clamp on Leak Sensor

HIOKI 9675 Clamp on Leak Sensor

For the LR5051, PW3198 and similar products.
Model : HIOKI 9675

Rated primary current

AC 10 A (for leak current measurement, 50/60 Hz)

Max. allowable input (45-66 Hz)

Max. 10 A of continuous input

Rated output current

AC 100 mV/A

Amplitude accuracy (45-66 Hz)

±1.0 % rdg. ±0.005 % f.s.

Phase accuracy

±5 ° (at 50 Hz or 60 Hz)

Frequency characteristics

40 Hz to 5 kHz: ± 5%

(Add to amplitude accuracy)

Max. rated voltage to earth

40 Hz to 5 kHz: ± 5%

(Add to amplitude accuracy)

Core diameter

φ 30 mm (1.18 in)

Dimensions and mass

60 mm (2.36 in)W × 112.5 mm (4.43 in)H × 23.6 mm (0.93 in)D, 160 g (5.6 oz), Cord length: 3 m (9.84 ft)

Accessories

Instruction manual ×1

For branch circuits

Related Products

HIOKI CT9557 Sensor Unit

HIOKI CT9557 Sensor Unit

HIOKI 3273-50 Clamp on Probe

HIOKI 3273-50 Clamp on Probe