HIOKI 9669 Current on Probe
• Measure up to 1000 A
|
Rated measurement current |
1000 A AC |
|
Max. measurement current |
Continuous 1000 A (45 to 66 Hz) |
|
Output rate |
0.5 mV AC/ A |
|
Amplitude accuracy (45 to 66 Hz) |
±1.0% rdg. ±0.01% f.s. |
|
Phase accuracy |
±1° (45 Hz to 5 kHz) |
|
Amplitude frequency characteristics |
Within ±2% at 40 Hz - 5 kHz (deviation from accuracy) |
|
Max. rated voltage to earth |
600 V AC rms or less |
|
Measurable conductor diameter |
φ 55 mm (2.17 in) or less 80 × 20 mm, Buss bars |
|
Operating temperature and humidity |
0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation) |
|
Dustproofness and waterproofness |
N/A |
|
Dimensions and mass |
99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm (1.65 in)D, 590 g (20.8 oz) Cord length 3 m (9.84 ft), Output terminal: BNC |
• For inverter devices or commercial power lines
• Measure up to 1000 A