HIOKI FT3151 Ground Resistance Tester
• Wide measurement range for 0 to 1150 Ω, based on EN standard
• Switchable measurement frequency to reduce the effects of power supply harmonics
• Dramatically faster setup: Comes with improved grounding rods and cord winders.
|
Measurement system |
AC potentiometer method, Three-electrode method/ two-electrode method (switchable) Measuring frequency: 575 Hz/ 600 Hz Measurement current: Three-electrode method: 15 mA rms or less; Two-electrode method: 3 mA rms or less Open circuit voltage: 50 V AC rms or less |
AC potentiometer method, Three-electrode method/ two-electrode method (switchable) Measuring frequency: 575 Hz/ 600 Hz Measurement current: Three-electrode method: 15 mA rms or less; Two-electrode method: 3 mA rms or less Open circuit voltage: 50 V AC rms or less |
AC potentiometer method, Three-electrode method/ two-electrode method (switchable) Measuring frequency: 575 Hz/ 600 Hz Measurement current: Three-electrode method: 15 mA rms or less; Two-electrode method: 3 mA rms or less Open circuit voltage: 50 V AC rms or less |
|
Measurement range |
10 Ω (0 to 11.5 Ω) |
100 Ω (0 to 115 Ω) |
1000 Ω (0 to 1150 Ω) |
|
Nominal Deviation |
±0.25 Ω |
±2.5 Ω |
±25 Ω |
|
Functions |
Auxiliary earth resistance check S (P)/ H(C) |
Auxiliary earth resistance check S (P)/ H(C) |
Auxiliary earth resistance check S (P)/ H(C) |
|
Earth potential measurement |
0 to 30 V, Nominal Deviation: ±3.0 % f.s. |
0 to 30 V, Nominal Deviation: ±3.0 % f.s. |
0 to 30 V, Nominal Deviation: ±3.0 % f.s. |
|
Power supply |
LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle) |
LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle) |
LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle) |
|
Dimensions and mass |
164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D, 760 g (26.8 oz) |
164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D, 760 g (26.8 oz) |
164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D, 760 g (26.8 oz) |
|
Accessories |
Auxiliary Earthing Rod L9840 (2 piece set) ×1, Measuring cable L9841 (alligator clip, black 4 m (13.12 ft)), Measurement Cable L9842-11 (yellow 10 m (32.81 ft), equipped with winder), Measurement Cable L9842-22 (red 20 m (65.62 ft), equipped with winder) ×1, LR6 (AA) Alkaline battery ×6, Carrying Case C0106 ×1, Instruction manual ×1 |
Auxiliary Earthing Rod L9840 (2 piece set) ×1, Measuring cable L9841 (alligator clip, black 4 m (13.12 ft)), Measurement Cable L9842-11 (yellow 10 m (32.81 ft), equipped with winder), Measurement Cable L9842-22 (red 20 m (65.62 ft), equipped with winder) ×1, LR6 (AA) Alkaline battery ×6, Carrying Case C0106 ×1, Instruction manual ×1 |
Auxiliary Earthing Rod L9840 (2 piece set) ×1, Measuring cable L9841 (alligator clip, black 4 m (13.12 ft)), Measurement Cable L9842-11 (yellow 10 m (32.81 ft), equipped with winder), Measurement Cable L9842-22 (red 20 m (65.62 ft), equipped with winder) ×1, LR6 (AA) Alkaline battery ×6, Carrying Case C0106 ×1, Instruction manual ×1 |
• Three-electrode method, Two-electrode method (Simple Measurement)
• Wide measurement range for 0 to 1150 Ω, based on EN standard
• Switchable measurement frequency to reduce the effects of power supply harmonics
• Dramatically faster setup: Comes with improved grounding rods and cord winders.