• HIOKI 9272 Current on Probe

HIOKI 9272 Current on Probe

9272-10 20/200 A AC, PL23 terminal
9272-05 20/200 A AC, ME15W terminal
Model : HIOKI 9272

Rated current

20 A AC, or 200 A AC (selectable)

Max. allowable input

50 A rms (at 20 A range), 300 A rms (at 200 A range)

Frequency characteristics

1 Hz (±2 % rdg. ±0.1 % f.s.) to 100 kHz (±30 % rdg. ±0.1 % f.s.)

Amplitude and Phase accuracy

Amplitude: ±0.3 % rdg. ±0.01 % f.s. Phase: ±0.2 ° (45 to 66 Hz)

Output voltage

2 V/20 A rated current range, or 2 V/200 A rated current range

(voltage output with the Sensor Unit, use with a device having a 1 MΩ input resistance or higher)

Max. rated voltage to earth

600 V rms (CAT III)

Core diameter

φ 46 mm (1.81 in)

Power supply

±11 V to ±15 V DC (Power suppled via the Sensor Unit, which supports 100 to 240 V AC)

Power consumption

5 VA Max. (when measuring 200 A)

Dimensions and mass

78 mm (3.07 in) W × 188 mm (7.40 in) H × 35 mm (1.38 in) D, 430 g (15.2 oz), cord length: 3 m (9.84 ft)

Accessories

Carrying case 9355 ×1, Instruction manual ×1, Mark bands ×6

• Superior low frequency and phase characteristics suitable for testing the current and power of inverter control devices

• Wide 1 Hz to 100 kHz frequency bandwidth perfect for harmonic analysis, FFT analysis and waveform monitoring (AC only)

Related Products

HIOKI 9657-10 Clamp on Leak Sensor

HIOKI 9657-10 Clamp on Leak Sensor

HIOKI 3276 Current on Probe

HIOKI 3276 Current on Probe

HIOKI 9695-03 current sensor

HIOKI 9695-03 current sensor

HIOKI 9018-50 Current on Probe

HIOKI 9018-50 Current on Probe