FLOWLINE UG01-03 Reflective Ultrasonic Multi-Function Liquid Level Sensor
Fail-safe diagnostics with selectable relay and signal outputs
Narrow 2” (5cm) beam width for applications with limited space
|
|
UG01 |
UG03 |
|
Range |
1.5” to 4.9’ (3.8cm to 1.5m) |
4” to 9.8’ (10.1cm to 3m) |
|
Accuracy |
0.125” (3mm) |
± 0.2% |
|
Resolution |
0.019” (0.5mm) |
0.039” (1mm) |
|
Dead band |
1.5” (3.8cm) |
4” (10.1cm) |
|
Beam width |
2” (5cm) |
2” (5cm) |
|
Configuration |
WebCal® PC Windows® USB® 2.0 |
WebCal® PC Windows® USB® 2.0 |
|
Memory |
Non-volatile |
Non-volatile |
|
Supply voltage |
14-28 VDC |
14-28 VDC |
|
Max. consumption |
0.5W |
0.5W |
|
Loop resistance |
500 ohms @ 24 VDC |
500 ohms @ 24 VDC |
|
Signal output |
4-20mA, two-wire |
4-20mA, two-wire |
|
Signal invert |
4-20mA or 20-4mA |
4-20mA or 20-4mA |
|
Signal fail-safe |
4mA, 20mA, 21mA, 22mA, hold last |
4mA, 20mA, 21mA, 22mA, hold last |
|
Enclosure rating |
Type 6P (IP68) |
Type 6P (IP68) |
|
Compliance |
CE, RoHS |
CE, RoHS |
lOffered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
lFail-safe diagnostics with selectable relay and signal outputs
lNarrow 2” (5cm) beam width for applications with limited space
lCorrosion resistant PVDF transducer and compact PP enclosure
lShort 1.5” (3.8cm) dead band maximizes tank filling capacity
lAutomatic temperature compensation from -40º to 80º C.
lFour programmable relays with embedded level control logic
n1 pump or valve with 3 alarms
n2 pumps lead-lag with 2 alarms
n2 pumps duplexing with 2 alarms
n4 independent switch point alarms