• HIOKI PW6001 Power Analyzer

HIOKI PW6001 Power Analyzer

• Exclusive current sensor phase shift function lets you maintain accuracy even in high frequency, low power factor applications
• Basic accuracy of ±0.02%*1 for power measurement
• *1 PW6001 accuracy only. Instrument delivers accuracy of ±0.07% even after the current sensor accuracy has been added.
Model : HIOKI PW6001

Measurement line type

Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire

Number of input channels

Max. 6 channels; each input unit provides 1 channel for simultaneous voltage and current input

(Voltage measurement unit: Photoisolated input, resistance voltage divider, Current measurement unit: Isolated input from current sensor)

Measurement items

Voltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk)

Harmonic measurement: Harmonic active power, select calculation order

from 2nd order to 100th order

Waveform recording: Voltage and current waveforms/ Motor pulse: Always 5 MS/s

Motor waveforms: Always 50 kS/s, 16 bits

Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor

waveforms)

Motor analysis (PW6001-11 to -16 only): Voltage, Torque, Rotation, Frequency, Slip, or Motor output

Measurement range

Voltage range: 6 to 1500 V, 8 ranges

Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor)

Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor)

Power range: 2.40000W to 4.50000MW (depends on combination of voltage and current range)

Frequency range: 0.1 Hz to 2 MHz

Basic accuracy

Voltage: ±0.02 % rdg. ±0.02 % f.s.

Current: ±0.02 % rdg. ±0.02 % f.s. + current sensor accuracy

Active power: ±0.02 % rdg. ±0.03 % f.s. + current sensor accuracy

Synchronization frequency range

Power measurement: 0.1 Hz to 2 MHz

Harmonic measurement: 45 Hz to 66 Hz (IEC standard mode), 0.1 Hz to 300 kHz (Wideband mode)

Frequency band

DC, 0.1 Hz to 2 MHz

Data update rate

Power measurement: 10 ms/ 50 ms/ 200 ms

Harmonic measurement: 200 ms (IEC standard mode), 50 ms (Wideband mode

Data save interval

OFF, 10 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes

User-selected from all measured values, including harmonic measured values,

Specified measured values can be saved in internal memory or USB flash drive

External interfaces

USB (memory), LAN, GP-IB, RS-232C (for communication/LR8410 link), External control ,Synchronization control

Logger connectivity

Sends measured values wirelessly to logger by using a Bluetooth® wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers), Ver. 2.0 and later

Power supply

100 to 240 V AC, 50/60 Hz, 200 VA max

Dimensions and mass

430 mm (16.93 in)W × 177 mm (6.97 in)H × 450 mm (17.72 in)D, 14 kg (49.4 oz) (PW6001-16)

Accessories

Instruction Manual ×1, Power cord ×1, D-sub connector × 1 (PW6001-1x only)

   Exclusive current sensor phase shift function lets you maintain accuracy even in high frequency, low power factor applications

   Basic accuracy of ±0.02%*1 for power measurement

   *1 PW6001 accuracy only. Instrument delivers accuracy of ±0.07% even after the current sensor accuracy has been added.

   High noise resistance and stability (80 dB/100 kHz CMRR, ±0.01%/°C temperature characteristics)

   Accurate measurement even when the load is characterized by large fluctuations; TrueHD 18-bit resolution

   10 ms data refresh while maintaining maximum accuracy (using a specially designed IC to make all measurements independently while performing simultaneous calculations.)

   DC accuracy of ±0.07%, which is key for stable, accurate efficiency measurement

   Wide frequency bandwidth of DC, or 0.1 Hz to 2 MHz

   Achieve true frequency analysis with high-speed 5MS/s sampling (18 bit)

   Synchronize 2 units for up to 12 channels*2 in real time

   *2 Two 6-channel models can be connected with an optical connection cable

   Special triggers to enable waveform analysis and motor analysis without the need for an oscilloscope

   Wideband harmonic analysis up to the 100th order with a 1.5 MHz band

   Send measured values to HIOKI data loggers using a Bluetooth® wireless technology compatible adapter (LR8410 Link-compatible products), Ver. 2.0 and later

Related Products

HIOKI PW3360 Clamp-on Power Logger

HIOKI PW3360 Clamp-on Power Logger

HIOKI PW3336 Power Meter

HIOKI PW3336 Power Meter

HIOKI PW3335 Power Meter

HIOKI PW3335 Power Meter

HIOKI PW9100 AC/DC Current Box

HIOKI PW9100 AC/DC Current Box

HIOKI 3169 Clamp-on Power Meter

HIOKI 3169 Clamp-on Power Meter

HIOKI PW3337 Power Meter

HIOKI PW3337 Power Meter